IMO MSC.1/Circ.1533
IMO MSC.1/Circ.1533
Revised Guidelines on Evacuation Analysis for New and Existing Passenger Ships (IMO MSC.1/Circ.1533, 6 June 2016, Annex 3, Appendix 2 (Guidance on validation/verification of evacuation simulation tools))
Reference: International Maritime Organization (2016). Revised guidelines on evacuation analysis for new and existing passenger ships. MSC.1/Circ.1533, 6 June 2016. https://edocs.imo.org/Final%20Documents/English/MSC.1-CIRC.1533%20(E).docx (Page numbers are the printed page numbers of Annex 3 (“Annex 3, page n”). Tests are cited by test number and paragraph of Appendix 2.)
Verification only; no validation comparisons have been run (#165).
Component testing (Tests 1-7)
| Test | Title | Status | Page |
|---|---|---|---|
| IMO 1 | Maintaining a set walking speed in a corridor | PASS | Open test page |
| IMO 2 | Maintaining a set walking speed up a staircase | PASS | Open test page |
| IMO 3 | Maintaining a set walking speed down a staircase | PASS | Open test page |
| IMO 4 | Exit flow rate | PASS | Open test page |
| IMO 5 | Response duration | PASS | Open test page |
| IMO 6 | Rounding corners | PASS | Open test page |
| IMO 7 | Assignment of population demographics | PASS | Open test page |
Qualitative verification (Tests 8-12)
| Test | Title | Status | Page |
|---|---|---|---|
| IMO 8 | Counterflow: two rooms connected by a corridor | PASS | Open test page |
| IMO 9 | Exit flow: crowd dissipation from a large public room | PASS | Open test page |
| IMO 10 | Exit route allocation | PASS | Open test page |
| IMO 11 | Staircase | PENDING | Open test page |
| IMO 12 | Flow-density relation | PENDING | Open test page |